CTE DB-HS6 Regulation
Spanish Technical Building Code - Radon Protection
Complete guide to Spanish radon protection regulations in construction. CTE DB-HS6 establishes mandatory requirements for new buildings and renovations in radon risk zones.
What is CTE DB-HS6?
The Basic Document on Health - Section 6 (DB-HS6) of the Technical Building Code establishes requirements for protection against radon exposure inside buildings. It was approved by Royal Decree 732/2019 on December 20, 2019, as transposition of Directive 2013/59/EURATOM.
This regulation has been mandatory since September 16, 2020 for all new construction and for extensions, changes of use and renovations of existing buildings located in municipalities classified as risk zones.
The main objective is to limit the foreseeable risk of inadequate radon exposure from the ground inside buildings, establishing a maximum reference level of 300 Bq/m³ as annual average.
Key points of the regulation
Entry into force
Mandatory since September 16, 2020 for all new construction in risk zones.
Reference level
The reference level is 300 Bq/m³ as an annual average. It is not a hard limit, but the value above which action is required.
Scope of application
New buildings, extensions, changes of use and renovations in classified zones.
Legal basis
Royal Decree 732/2019 transposing European Directive 2013/59/EURATOM.
Risk zones
Appendix B lists municipalities with a significant probability of exceeding the reference level and classifies them as Zone I or Zone II. Municipalities not listed are unclassified.
Mandatory verification
Ventilated containment spaces and ground depressurisation require an effectiveness check by measurement after the works. A protective barrier alone does not.
Radon zone classification
The CTE classifies Spanish municipalities into two zones according to the ground's radon potential, determining mandatory protection measures for each case.
Zone I
Protective barrier, or ventilated air chamber
Municipalities where the annual average radon concentration in buildings may exceed 300 Bq/m³. Basic protection measures are required.
Mandatory requirements:
- Protection barrier between the ground and habitable areas
- Alternatively: air chamber ventilated to the outside
- If the air chamber is chosen, it must be separated from habitable rooms by an enclosure free of cracks or fissures
Zone II
Protective barrier plus an additional system
Municipalities with significant radon presence where enhanced protection measures are required. Higher probability of exceeding the reference level.
Mandatory requirements:
- Protection barrier between the ground and habitable areas
- Mandatory additional system: ventilated containment space
- Or a ground depressurisation system with mechanical extraction
- Effectiveness check by measurement after the works
Check Your Radon Zone
Search for your municipality to know its radon classification
Scope of application
CTE DB-HS6 clearly defines which buildings and situations are subject to its radon protection requirements.
Applies to:
- New buildings in Zone I and Zone II
- Extensions to existing buildings, applying only to the new part
- Changes of use involving habitable areas
- Refurbishment works that increase radon protection or alter the original protection, in the affected area
- Comprehensive rehabilitations in classified zones
Exceptions:
- Non-habitable areas (garages, storage without prolonged use)
- Habitable rooms separated from the ground by intermediate open spaces with ventilation equivalent to outdoors
- Buildings located outside Zone I and Zone II
- Minor renovations not affecting the envelope
CTE Detector Calculator
Calculate the number of detectors needed to verify CTE DB-HS6 compliance in your building.
Calculate required detectorsProtection measures
CTE DB-HS6 establishes different technical solutions for radon protection, varying according to the risk zone.
Protection barrier
Continuous radon-impermeable membrane placed under the slab or crawl space, sealing all joints and penetrations.
Zone I and Zone IIVentilated air chamber
Space ventilated to the outside located between the ground and habitable areas, with permanent ventilation openings.
Zone I (alternative)Ventilated containment space
Additional air chamber under the protection barrier, connected to the outside through ventilation ducts.
Zone II (one of two options)Ground depressurisation system
A network of sumps or perforated pipes beneath the slab, over a granular fill layer, connected to an extraction duct and a mechanical extraction system.
Zone II (one of two options)Effectiveness check
When a ventilated containment space or ground depressurisation is installed, its effectiveness must be checked by measuring radon after the works, in line with appendix C.
Required for those two solutionsPenetration sealing
Airtight treatment of all joints, cracks and installation penetrations crossing the barrier.
Zone I and Zone IIMeasurement requirements
Verification through measurement is mandatory to check the effectiveness of implemented protection measures.
Measurement conditions
- Minimum exposure period: 2 months (3 recommended)
- Sampling zones on every below-grade floor with habitable rooms and on the two lowest floors above grade
- Avoid holiday periods or prolonged closure
- Detectors 50-180 cm above the floor, more than 30 cm from walls and doors and more than 10 cm from other objects
Laboratory requirements
Measurements must be performed by a laboratory with accreditation according to UNE-EN ISO/IEC 17025, granted by ENAC or equivalent recognized entity.
Radonova Laboratories is accredited to UNE-EN ISO/IEC 17025 by SWEDAC, the Swedish national accreditation body, valid in Spain through European mutual recognition.
Frequently asked questions
When is CTE DB-HS6 mandatory?
+
It has been mandatory since September 16, 2020 for all new construction, extensions, changes of use and renovations affecting the envelope in contact with the ground, provided the building is in a municipality classified as Zone I or Zone II.
What happens if my municipality is not classified?
+
If your municipality is not classified as Zone I or Zone II, there are no mandatory requirements under the CTE. However, radon measurement is recommended, especially in homes with basements or in direct contact with the ground, as localized elevated concentrations may exist.
Is measurement mandatory after completing construction?
+
It depends on the solution used. The building code requires an effectiveness check by measurement when a ventilated containment space or a ground depressurisation system is installed, which are the Zone II additional systems. If protection is provided by a barrier alone, the code does not require measurement, though it remains advisable. Since every Canary Island municipality in appendix B is Zone II, the check is the norm here.
How long should the measurement last?
+
The measurement must last a minimum of 2 months, though 3 months is recommended for better accuracy, preferably during the period from October to May. This provides a representative value of the annual average, compensating for seasonal variations.
What if the measurement exceeds 300 Bq/m³?
+
If 300 Bq/m³ is exceeded, protection must be reinforced and the space measured again to confirm it works. The building code grades the response in section 3.4: between one and two times the reference level, Zone I solutions apply; above twice the level, Zone II solutions. This may mean increasing the extraction rate, adding collection elements or improving ventilation.
Can I do the measurement myself?
+
For the measurement to have official validity under the CTE, it must be performed by an ISO 17025 accredited laboratory. Detectors must be supplied and analyzed by that laboratory. Private measurements without accreditation are not valid for regulatory compliance.
Need to comply with CTE DB-HS6?
We are official distributors of Radonova, an ISO/IEC 17025 accredited laboratory. We help you carry out the measurements required to comply with the Spanish Building Code.

Get in touch with us
Phone
922 575 171Opening hours
Monday to Friday, 7:00 to 15:00